• Skip to main content
CEP logo
  • Home
  • About Us
    • About Us
    • Organization Chart
    • Distributorships
  • Products
    • Geotechnical Sensors
      • Borehole Extensometers
        • Borros Anchor
        • CEP Magnet Extensometer
        • Slope Extensometer
        • Increx System
        • Rod Extensometer
        • Settlement Hook
        • Sondex
      • Geonor H10 Vane Shear Borer
      • Goodman Jack
      • Inclinometer
        • CEP Inclinometer Casing
        • Slope Inclinometer Casing
        • DataMateII Readout
        • Digitilt Inclinometer Probe
        • Horizontal Digitilt Probe
        • CEP Inclinometer Control Cable
        • DigiPro Software
        • EL In-Place Sensors
        • Horizontal EL IP Sensors
        • EL Sled Sensors
        • Spiral Sensor
        • uMonitor Software
        • uSlope Software
      • Piezometers
        • Bentonite Tablets
        • Casagrande Piezometer
        • Standpipe Piezometer
        • Pneumatic Piezometer
        • Vibrating Wire Piezometer
        • Multi Level VW Piezometer
        • Vented VW Pressure Transducer
      • Pressure Cells
        • Total Pressure Cell
        • Jackout Pressure Cell
        • Pressure Cells for Tunnels
        • Stress Station
      • Pocket Penetrometer
      • Settlement Cells
      • Soil Strainmeter
      • Torvane
    • Structural Sensors
      • Bassett Convergence System
      • Jointmeter and Crackmeter
        • 3-D Jointmeter
        • Avongard Crackmeters
        • VW Crackmeter
        • VW Embedment Jointmeter
      • Liquid Level System
      • Load Cells
      • Tape Extensometer
        • Anchor Bolt
      • Thermocouple
      • Tilt Sensors
        • EL Beam Sensor
        • EL Track Monitor
        • EL Tiltmeter
        • Portable Tiltmeter
        • TiltPlate
      • Strain Gauges
        • Embedment Strain Gauge
        • Spot-Weldable Strain Gauge
        • Arc-Weldable Strain Gauge
    • Readouts
      • CEP Water Level Indicator
      • Slope WLI
      • Digitilt DataMateII (For Inclinometers)
      • Digitilt 09 Indicator (For Tiltmeter)
      • EL Data Recorder
      • EL Nulling Device
      • Pneumatic Pressure Indicator
      • VW Data Recorder
    • Dataloggers
      • CR1000 Datalogger
      • CR800 Datalogger
      • DataTaker DT515 / DT615
      • Multiplexer
      • Real-Time Instrumentation Monitoring System
      • uMonitor Software
      • uGraph Software
      • VW MiniLogger
    • Vibration Monitors
      • Nomis MiniGraph 7000
      • Nomis SuperGraph
      • Nomis Mini SuperGraph
      • PMT EVA Elevator Vibration Monitor
      • PMT IMD-1 Step/Skirt Performance Index Device
    • Accessories
      • Signal Cable
    • Advanced Geosciences Inc
    • Jauntering- for Environmental Monitoring Products
    • Simpson Electric
  • Services
    • Calibration
    • Field Services
    • Rental
  • Contact Us

Slope Indicator - Pneumatic Indicator

Application

The 256 Pneumatic Pressure Indicator is used to activate and read pneumatic piezometers, total pressure cells, and settlement cells.

The indicator employs top quality components and is constructed to withstand many years of hard use.

Overview of Operation

Before leaving for site, check that the indicator's built-in tank is charged with gas. The built-in tank holds more than 180 liters of gas (6.25 SCF), which is suitable for busy reading schedules.

On site, set the pressure regulator. Proper regulation results in lower gas consumption and prevents damage to the pressure gauge.

Connect tubing from the transducer to the indicator using the quick-connect fittings. Turn on the gas to activate the transducer. Gas now flows down through the tubing to the transducer.

Wait for a return flow of gas from the transducer's vent tube, then shut off the gas. If you reading with flow, use the built-in precision flowmeter and flowrate valve to slow the flow of gas.

Wait for the pressure reading on the main gauge to stabilize, then write down the reading. It is good practice to take a second reading for verification.

Disconnect and move to the next transducer.


Indicator Options

Pressure Gauges: Choose a pressure gauge that meets your needs. Analog guages offer 0.25% accuracy; the digital gauges offer 0.05% accuracy.

Precision Flowmeter:
Use the precision flowmeter when reading with flow or when pressurizing long lines.

High Quality Components:
The 256 indicator is built for hard and long use. It employs the best quality tube fittings, tubing, valves, gauges, and tank.

Click to download datasheet | Manual

Our Products

  • Geotechnical Sensors
  • Structural Sensors
  • Readouts
  • Dataloggers
  • Vibration Monitors
  • Accessories
  • Advanced Geosciences Inc
  • Jauntering- for Environmental Monitoring Products
  • Simpson Electric

Office Address

30B Hillview Terrace
Singapore 669248
Tel: (65) 6760 1566
Fax: (65) 6760 5186
Email: sales@cep.com.sg

Get A Quote

get-now

  • Home
  • Terms & Conditions
  • Privacy Policy
  • Sitemap
  • Contact Us
Copyright © 2012 CEP. All Rights Reserved.