• Skip to main content
CEP logo
  • Home
  • About Us
    • About Us
    • Organization Chart
    • Distributorships
  • Products
    • Geotechnical Sensors
      • Borehole Extensometers
        • Borros Anchor
        • CEP Magnet Extensometer
        • Slope Extensometer
        • Increx System
        • Rod Extensometer
        • Settlement Hook
        • Sondex
      • Geonor H10 Vane Shear Borer
      • Goodman Jack
      • Inclinometer
        • CEP Inclinometer Casing
        • Slope Inclinometer Casing
        • DataMateII Readout
        • Digitilt Inclinometer Probe
        • Horizontal Digitilt Probe
        • CEP Inclinometer Control Cable
        • DigiPro Software
        • EL In-Place Sensors
        • Horizontal EL IP Sensors
        • EL Sled Sensors
        • Spiral Sensor
        • uMonitor Software
        • uSlope Software
      • Piezometers
        • Bentonite Tablets
        • Casagrande Piezometer
        • Standpipe Piezometer
        • Pneumatic Piezometer
        • Vibrating Wire Piezometer
        • Multi Level VW Piezometer
        • Vented VW Pressure Transducer
      • Pressure Cells
        • Total Pressure Cell
        • Jackout Pressure Cell
        • Pressure Cells for Tunnels
        • Stress Station
      • Pocket Penetrometer
      • Settlement Cells
      • Soil Strainmeter
      • Torvane
    • Structural Sensors
      • Bassett Convergence System
      • Jointmeter and Crackmeter
        • 3-D Jointmeter
        • Avongard Crackmeters
        • VW Crackmeter
        • VW Embedment Jointmeter
      • Liquid Level System
      • Load Cells
      • Tape Extensometer
        • Anchor Bolt
      • Thermocouple
      • Tilt Sensors
        • EL Beam Sensor
        • EL Track Monitor
        • EL Tiltmeter
        • Portable Tiltmeter
        • TiltPlate
      • Strain Gauges
        • Embedment Strain Gauge
        • Spot-Weldable Strain Gauge
        • Arc-Weldable Strain Gauge
    • Readouts
      • CEP Water Level Indicator
      • Slope WLI
      • Digitilt DataMateII (For Inclinometers)
      • DataMate MP Readout
      • Digitilt 09 Indicator (For Tiltmeter)
      • EL Data Recorder
      • EL Nulling Device
      • Pneumatic Pressure Indicator
      • VW Data Recorder
    • Dataloggers
      • CR1000 Datalogger
      • CR800 Datalogger
      • DataTaker DT515 / DT615
      • Multiplexer
      • Real-Time Instrumentation Monitoring System
      • uMonitor Software
      • uGraph Software
      • VW MiniLogger
    • Vibration Monitors
      • Nomis MiniGraph 7000
      • Nomis SuperGraph
      • Nomis Mini SuperGraph
      • PMT EVA Elevator Vibration Monitor
      • PMT IMD-1 Step/Skirt Performance Index Device
    • Accessories
      • Signal Cable
    • Advanced Geosciences Inc
    • Jauntering- for Environmental Monitoring Products
    • Simpson Electric
  • Services
    • Calibration
    • Field Services
    • Rental
  • Contact Us

Slope Indicator - Digitilt Datamate II

Application

The Digitilt DataMate II records data from Digitilt inclinometer probes, tiltmeters, and spiral sensors. It can store up to 320 surveys and operate 16 hours on freshly charged batteries.

The DataMate is designed for hard use in difficult environments. Electronic components are rated for extended temperatures. Connector sockets are located on the face panel, away from contact with mud, water, or snow. The case is sealed against condensation and humidity, and the bright, backlit display is visible under all lighting conditions.

The Digitilt DataMate II is the second generation of the DataMate. It maintains the same convenient form factor, but features updated electronics that provide significantly faster operation. It can store 160 installation headers and up to 320 surveys (32000 depths with 4 readings for each depth) and communicates with the PC via a USB port.

Overview of Operation

The Digitilt DataMate holds a list of inclinometer installations in memory. To begin a survey, the operator selects an installation from the list. The DataMate then displays the starting depth for the survey. The operator positions the inclinometer probe accordingly and checks the display. The display shows the depth in meters or feet, the A-axis reading, and the B-axis reading. When both readings are stable and ready to record, the DataMate displays a graphic ready signal.

The operator presses the hand-switch to record the readings (the hand switch allows the operator to keep both hands on the control cable). The DataMate beeps and displays the next depth. The operator raises the probe to this depth, and again, watches for the ready signal and records the reading. The operator repeats these steps until the survey is done.

Validating Data

The DataMate provides checksums and checksum statistics to help the operator validate the data set before leaving the site. Questionable readings can be verified and corrected by repositioning the inclinometer probe and re-recording the reading.

Retrieving Data

To transfer data from the DataMate to a PC, the operator runs the DataMate Manager program (DMM), which retrieves the data and stores it in a database for quick access. The DMM program also imports data files from previous Slope Indicator formats and also from G-TILT.

Processing Data

While the DataMate can calculate deviation and displacement for the top or bottom of the installation, more comprehensive processing must be performed on a computer.

DigiPro for Windows is a program designed specifically for this purpose. DigiPro dramatically reduces the time required to process data, eliminates repetitive work, and generates high resolution graphs.

Click to download datasheet | Manual for Readout | Manual for DMM Software

Our Products

  • Geotechnical Sensors
  • Structural Sensors
  • Readouts
  • Dataloggers
  • Vibration Monitors
  • Accessories
  • Advanced Geosciences Inc
  • Jauntering- for Environmental Monitoring Products
  • Simpson Electric

Office Address

30B Hillview Terrace
Singapore 669248
Tel: (65) 6760 1566
Fax: (65) 6760 5186
Email: sales@cep.com.sg

Get A Quote

get-now

  • Home
  • Terms & Conditions
  • Privacy Policy
  • Sitemap
  • Contact Us
Copyright © 2012 CEP. All Rights Reserved.