• Skip to main content
CEP logo
  • Home
  • About Us
    • About Us
    • Organization Chart
    • Distributorships
  • Products
    • Geotechnical Sensors
      • Borehole Extensometers
        • Borros Anchor
        • CEP Magnet Extensometer
        • Slope Extensometer
        • Increx System
        • Rod Extensometer
        • Settlement Hook
        • Sondex
      • Geonor H10 Vane Shear Borer
      • Goodman Jack
      • Inclinometer
        • CEP Inclinometer Casing
        • Slope Inclinometer Casing
        • DataMateII Readout
        • Digitilt Inclinometer Probe
        • Horizontal Digitilt Probe
        • CEP Inclinometer Control Cable
        • DigiPro Software
        • EL In-Place Sensors
        • Horizontal EL IP Sensors
        • EL Sled Sensors
        • Spiral Sensor
        • uMonitor Software
        • uSlope Software
      • Piezometers
        • Bentonite Tablets
        • Casagrande Piezometer
        • Standpipe Piezometer
        • Pneumatic Piezometer
        • Vibrating Wire Piezometer
        • Multi Level VW Piezometer
        • Vented VW Pressure Transducer
      • Pressure Cells
        • Total Pressure Cell
        • Jackout Pressure Cell
        • Pressure Cells for Tunnels
        • Stress Station
      • Pocket Penetrometer
      • Settlement Cells
      • Soil Strainmeter
      • Torvane
    • Structural Sensors
      • Bassett Convergence System
      • Jointmeter and Crackmeter
        • 3-D Jointmeter
        • Avongard Crackmeters
        • VW Crackmeter
        • VW Embedment Jointmeter
      • Liquid Level System
      • Load Cells
      • Tape Extensometer
        • Anchor Bolt
      • Thermocouple
      • Tilt Sensors
        • EL Beam Sensor
        • EL Track Monitor
        • EL Tiltmeter
        • Portable Tiltmeter
        • TiltPlate
      • Strain Gauges
        • Embedment Strain Gauge
        • Spot-Weldable Strain Gauge
        • Arc-Weldable Strain Gauge
    • Readouts
      • CEP Water Level Indicator
      • Slope WLI
      • Digitilt DataMateII (For Inclinometers)
      • Digitilt 09 Indicator (For Tiltmeter)
      • EL Data Recorder
      • EL Nulling Device
      • Pneumatic Pressure Indicator
      • VW Data Recorder
    • Dataloggers
      • CR1000 Datalogger
      • CR800 Datalogger
      • DataTaker DT515 / DT615
      • Multiplexer
      • Real-Time Instrumentation Monitoring System
      • uMonitor Software
      • uGraph Software
      • VW MiniLogger
    • Vibration Monitors
      • Nomis MiniGraph 7000
      • Nomis SuperGraph
      • Nomis Mini SuperGraph
      • PMT EVA Elevator Vibration Monitor
      • PMT IMD-1 Step/Skirt Performance Index Device
    • Accessories
      • Signal Cable
    • Advanced Geosciences Inc
    • Jauntering- for Environmental Monitoring Products
    • Simpson Electric
  • Services
    • Calibration
    • Field Services
    • Rental
  • Contact Us

Multiplexer

Application


MULTIPLEXER is mainly used to increase the number of input sensors for datalogger series such as Campbell Scientific CR1000/800 and others. The MULTIPLEXER is located between datalogger and sensors. By using the relay switch features, it sequentially scans and processes each incoming signal of sensors and transmits the signal to datalogger, which is same as other relay-switched multiplexers of worldwide makers'.

According to different type of sensors (including single-ended or differential with or without excitation voltage), each MULTIPLEXER can multiply the maximum sensor numbers as follow:

  • Up to 16 Slope Indicator's or other vibrating wire sensors through one vibrating wire interface and 32 Slope Indicator's or other vibrating wire sensors through two vibrating wire interfaces.
  • Up to 32 single-ended of differential sensors which do not require excitation voltage including thermocouples, soil heat flux flow transducers.
  • Up to 48 single-ended sensors which require excitation voltage including some half bridge sensors.
  • Up to 16 CEP loadcells which require excitation voltage including full bridge.
  • Up to 16 single-ended or differential sensors which require excitation voltage including full bridge and half bridge sensors.

Physical Description


The MULTIPLEXER is housed in a 230mm x 130mm x 56mm anodized aluminum case. The aluminum case is intended to reduce temperature gradients across the MULTIPLEXER's terminal strips. This is typically important when thermocouples are being wired and multiplexed to MULTIPLEXER.

Specification

  • POWER: 12VDC
  • Power Consumption: Quiescent: 5.8mA. Active: 30mA
  • Reset: a continous signal of 3.5 Vdc < voltage < 12 Vdc holds MULTIPLEXER in an active status. A signal voltage below 0.9 Vdc deactivates MULTIPLEXER.
  • Clock: a 5 Vdc pulse signal can make MULTIPLEXER work.
  • Operation Temperature: -40 to +65 degree C
  • Operation Humidity:0 -95%, non-condensing.
  • Dimension: 230mm (L), 130mm (W), 56mm (D).
  • Weight: (approximately) 790g
  • Expendability: 6 - 8 MULTIPLEXERS

Click to download datasheet

Our Products

  • Geotechnical Sensors
  • Structural Sensors
  • Readouts
  • Dataloggers
  • Vibration Monitors
  • Accessories
  • Advanced Geosciences Inc
  • Jauntering- for Environmental Monitoring Products
  • Simpson Electric

Office Address

30B Hillview Terrace
Singapore 669248
Tel: (65) 6760 1566
Fax: (65) 6760 5186
Email: sales@cep.com.sg

Get A Quote

get-now

  • Home
  • Terms & Conditions
  • Privacy Policy
  • Sitemap
  • Contact Us
Copyright © 2012 CEP. All Rights Reserved.