CEP LOAD CELLS

Application

The Centre Hole Load Cells are compact sensors for measuring loads in tie backs, foundation anchors, struts, rock bolts, tunnel supports and loading pile tests. Multiple high resistance strain gauges are bonded to high strength heat treated steel rings in a full strain gauge bridge circuit. Each load cell has two in-built distribution rings to reduce errors due to off-centre loading. The load cells can be calibrated and read using a Vishay P3500 or P3 digital strain indicator or data loggers.

 

Specifications

Material: High strength steel

Linearity : +/- 0.2%  

 

STRUT LOAD CELLS

Capacity

(tons)

I. D.

(mm)

O. D.

(mm)

Height

(mm)

50

50

68

115

100

50

76

115

150

50

84

115

200

50

90

115

250

50

96

115

300

50

102

115

350

50

108

115

GROUND ANCHOR LOAD CELLS

Capacity

(tons)

I.D.

(mm)

O.D.

(mm)

Height

(mm)

100

100

118

125

150

125

148

125

200

150

173

125

LOAD CELLS FOR PILE LOAD TEST

400

69

125

160

500

69

137

160

600

69

141

160

1000 100 189 230

 Note: Custom capacities, diameters and heights for load are available upon request.  

 