ANCHOR BOLT

Application

Ring Anchor is anchored into concrete wall or ceiling for suspending ceiling and other items. It can be also be used as tape extensometer reference points installed at measurement stations along the tunnel or structure.

 

Advantages
  • Quick and easy setting

  • Automatic follow-up expansion

  • Fire resistance

 

Specification

SPECIFICATION                               

 

Model No.

Material

Hole Diameter, do(mm)

Hole Depth, h1 (mm)

Stand-off from surface to centre-line. (mm)

Shank diameter,  (mm)

Package Contents

CEP2-5

Steel, galvanized to 5 microns.

8

50

12 - 15

5

100

 

 

 

 

 

 

Basic Loading Data (For a Single Anchor)

All data on this page applies to

o    Concrete: Fcc >/= 20N/mm2

o    Table values are only for tensile loading

o    No edge distance and spacing influence

Recommended load, Lrec (kN):

Tensile, NRec = 0.8 KN

Setting details
Min. hole depth, h1 (mm) 50
Min. anchorage depth, hnom (mm) 40
Hole diameter, do (mm) 8
Distance to wall/ceiling, F (mm) 12 - 15
Anchor length, l (mm) 66
Bolt diameter, d (mm) 5
 
* Click to download datasheet [Anchor Bolt]